On 04/15/2014 12:28 AM, Scott Wood wrote:
On Mon, 2014-04-14 at 14:35 +0200, Martijn de Gouw wrote:
+       lbc: localbus@ffe124000 {
+               reg = <0xf 0xfe124000 0 0x1000>;
+               ranges = <0 0 0xf 0xef800000 0x800000>;
+
+               flash@0,0 {
+                       #address-cells = <1>;
+                       #size-cells = <1>;
+                       compatible = "cfi-flash";
+                       reg = <0 0 0x00800000>;
+                       bank-width = <2>;
+                       device-width = <2>;
+                       partition@rcw {
+                               label = "rcw";
+                               reg = <0x00000000 0x00020000>;
+                       };
+                       partition@fman-ucode {
+                               label = "fman-ucode";
+                               reg = <0x00020000 0x00020000>;
+                       };
+                       partition@user {
+                               label = "user";
+                               reg = <0x00040000 0x00680000>;
+                       };
+                       partition@env0 {
+                               label = "env0";
+                               reg = <0x006c0000 0x00020000>;
+                       };
+                       partition@env1 {
+                               label = "env1";
+                               reg = <0x006e0000 0x00020000>;
+                       };
+                       partition@u-boot {
+                               label = "u-boot";
+                               reg = <0x00700000 0x00080000>;
+                       };
+                       partition@u-boot-backup {
+                               label = "u-boot-backup";
+                               reg = <0x00780000 0x00080000>;
+                       };

These are not valid unit addresses.  Regardless, please don't put
partition info in the dts.

How is this different than the partitions defined in i.e. p4080ds.dts?
Of course I can remove them from the dts, but where should they be defined?

--