On Fri, Dec 12, 2003 at 11:56:09AM +0100, Stefan Roese wrote: > > Davey! > > No, we didn't solve this problem so far. Eugene did some tests on an > ppc440 board and had no problems with the multiple enet devices. So it > seems to be 405ep related! I still have to send some debug output to > Eugene (hopefully today)!
[I haven't followed the thread but new EMAC driver and 405EP rings a bell] It's possible that the new method in which OCP code handles OCP device dependencies has a bug. 405ep is a special case since it requires a particular EMAC device to provide MDIO operations for both EMACs. 440gp/gx don't follow this code path. -Matt ** Sent via the linuxppc-embedded mail list. See http://lists.linuxppc.org/