My configuration is as follows: _______________________ | ROUTER | | ___ ___ | |_____| |_______| |___| LAN WAN /\ /\ | | Stand Alone Company Windows System Network (eth0) (eth1)
I have a udhcp server running on eth0. When I give the command on the windows machine "ipconfig /renew", the router assigns an IP address to the System in the range 192.168.1.x while the router itself has the IP 192.168.1.1 (default). I can ping the router from the system and vice-versa. I manually assigned a static IP to eth1 as 172.19.56.x insync with the company IP address scheme. I can ping from the router to any other system on the network. Now when I try to ping a system or eth1 from the windows machine I get a time out. But if I have to manually assign an IP to the windows machine(ie not through the udhcp server) I am able to ping eth1 and any other system on the network. Any ideas as to how and why? If you need more inform please let me know... Atit DISCLAIMER: This email (including any attachments) is intended for the sole use of the intended recipient/s and may contain material that is CONFIDENTIAL AND PRIVATE COMPANY INFORMATION. Any review or reliance by others or copying or distribution or forwarding of any or all of the contents in this message is STRICTLY PROHIBITED. If you are not the intended recipient, please contact the sender by email and delete all copies; your cooperation in this regard is appreciated.