On Jul 14, 2008, at 7:14 AM, selvamuthukumar v wrote:

From, arch/powerpc/boot/dts/mpc8313erdb.dts,

212                 enet0: [EMAIL PROTECTED] {
                                  .
                                  .
219                         interrupts = <37 0x8 36 0x8 35 0x8>;
                                  .
                                  .
222                 };
223
224                 enet1: [EMAIL PROTECTED] {
                                  .
                                  .
231                         interrupts = <34 0x8 33 0x8 32 0x8>;
                                  .
234                 };
235

But as per 8313 Reference manual interrups 32, 33, 34 are for
[EMAIL PROTECTED] and 35, 36, 37 are for [EMAIL PROTECTED] Any idea why 
interrupt
numbers are swapped for enet0 and enet1?

I believe different revisions of the part had different mappings.

- k