On Tue, Feb 17, 2015 at 06:15:59PM +0100, Axel Holzinger wrote:
> I came across Windows implementations where only the sequence id is used and
> IMHO this is not sufficient (thinking of different domains on the same
> network).

Yes, your are right, that is insufficient.  Think of a master that
receives multiple Delay_Req events from different slaves.

Unfortunately, there are hardware implementations that also provide
sequenceId only.

Thanks,