On Tue, Feb 17, 2015 at 06:15:59PM +0100, Axel Holzinger wrote: > I came across Windows implementations where only the sequence id is used and > IMHO this is not sufficient (thinking of different domains on the same > network).
Yes, your are right, that is insufficient. Think of a master that receives multiple Delay_Req events from different slaves. Unfortunately, there are hardware implementations that also provide sequenceId only. Thanks, Richard ------------------------------------------------------------------------------ Download BIRT iHub F-Type - The Free Enterprise-Grade BIRT Server from Actuate! Instantly Supercharge Your Business Reports and Dashboards with Interactivity, Sharing, Native Excel Exports, App Integration & more Get technology previously reserved for billion-dollar corporations, FREE http://pubads.g.doubleclick.net/gampad/clk?id=190641631&iu=/4140/ostg.clktrk _______________________________________________ Linuxptp-devel mailing list Linuxptp-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/linuxptp-devel