On Thu, 2015-02-26 at 08:29 +0100, Richard Cochran wrote:
> @Jason: Got private email this week from another person using the
> I217-LM.  Here is what they wrote:
> 
>   The offset all of a sudden jumps be 40000+ seconds. I would think
>   that if it was an issue with just reading the timer that the servo
>   would help throw out spurious values like that, so I suspect we are
>   somehow actually corrupting the timer.  We wrote our own little test
>   program that only calls get time on the PTP timer, and when we call
>   it more frequently than 1us is when we really start corrupting the
>   timer with a vengeance.
> 
> So that gives a clear cut test case that triggers the bug.
> 
> Thanks,
> Richard

Thanks Richard! I will pass this on.

Regards,
Jake
------------------------------------------------------------------------------