> Miroslav Lichvar <mlich...@redhat.com> wrote:
> > The default precision of the SHM refclock in chrony is 1 microsecond,
> > it won't report jitter smaller than that. Add "precision 1e-9" to the
> > SHM line in your chrony.conf to fix that.
> 
> Ah, that explains a lot.  Will that fix the jitter computation?

Yes, the +/- value in the chronyc sources output should be smaller
than 1 us now. It's mostly a cosmetic issue, it likely won't have any
noticeable effect on the synchronization. The precision is the minimum
allowed value of dispersion to avoid zero dispersion with low
resolution refclocks, e.g. with microsecond SHM it is possible to get
several samples with 0 offset, the dispersion would be zero and it
would then break all kinds of things.

-- 
Miroslav Lichvar

------------------------------------------------------------------------------