On Mon, Mar 27, 2017 at 10:27:44AM +0200, Stefan Lange wrote:
> Hi Miroslav,
> 
> I compiled and tested your patch.
> 
> Unfortunately it did not change / improve the behaviour.

> LIST_FOREACH(clock id: ffffffcb, device: eth2, &node->clocks, list)
> node->master->clkid: ffffffd3, device: eth1
> phc2sys[4637.685]: [0:eth1+eth2] phc offset         5 s0 freq      +0

Oh, I see. The ID encodes the file descriptor, not the PHC index.

Can you please try the V2 patch?

-- 
Miroslav Lichvar

------------------------------------------------------------------------------