On Fri, Feb 26, 2021 at 06:54:07AM +0000, Karthikkumar V wrote: > This code changes brings in the ability to program the acceptable > clockClass threshold beyond which device will move to holdover/free-run. > Default clockClass threshold is 248. > Example Use-Case: > This is needed in the cases where T-SC/T-BC Slave might want to listen > only on PRC clockCLass and anything beyond that might not be acceptible > and would want to go to holdover (with SyncE backup or internal oscillator). > > Signed-off-by: Karthikkumar V <[email protected]> > Signed-off-by: Ramana Reddy <[email protected]>
Applied. Thanks, Richard _______________________________________________ Linuxptp-devel mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/linuxptp-devel