On Fri, Feb 26, 2021 at 06:54:07AM +0000, Karthikkumar V wrote: > This code changes brings in the ability to program the acceptable > clockClass threshold beyond which device will move to holdover/free-run. > Default clockClass threshold is 248. > Example Use-Case: > This is needed in the cases where T-SC/T-BC Slave might want to listen > only on PRC clockCLass and anything beyond that might not be acceptible > and would want to go to holdover (with SyncE backup or internal oscillator). > > Signed-off-by: Karthikkumar V <kval...@altiostar.com> > Signed-off-by: Ramana Reddy <rre...@altiostar.com>
Applied. Thanks, Richard _______________________________________________ Linuxptp-devel mailing list Linuxptp-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/linuxptp-devel