On Fri, Feb 26, 2021 at 06:54:07AM +0000, Karthikkumar V wrote:
> This code changes brings in the ability to program the acceptable
> clockClass threshold beyond which device will move to holdover/free-run.
> Default clockClass threshold is 248.
> Example Use-Case:
> This is needed in the cases where T-SC/T-BC Slave might want to listen
> only on PRC clockCLass and anything beyond that might not be acceptible
> and would want to go to holdover (with SyncE backup or internal oscillator).
> 
> Signed-off-by: Karthikkumar V <kval...@altiostar.com>
> Signed-off-by: Ramana Reddy <rre...@altiostar.com>

Applied.

Thanks,
Richard


_______________________________________________
Linuxptp-devel mailing list
Linuxptp-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/linuxptp-devel