On Thu, Mar 17, 2022 at 10:16:03AM +0000, Geva, Erez wrote: > There is no generic sync. > > So each user need to define a 'sync' that match to its system needs.
A user-defined sync service could be based off of your pmc lib. Maybe that would be the place to have one or two examples? Thanks, Richard _______________________________________________ Linuxptp-devel mailing list Linuxptp-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/linuxptp-devel