On Mon, May 02, 2022 at 11:06:05AM +0200, Arkadiusz Kubalewski wrote: > Add main code of synce4l - user space application implementing > standard - Recommendation ITU-T G.8264/Y.1364. > On init the application parses SyncE config file and initializes > a synce_clock with SyncE devices and configured ports. > synce_clock is later polled until application termination. > > Add documentation in form of Linux manual and 'synce4l_README.md'.
> +++ b/synce4l.8 > @@ -0,0 +1,239 @@ > +.IP external_input_ext_QL > +Extended Quality Level for "external input" mode. > +.P > +.RS > +Extended Quality Level for "external input" mode. This sentence is duplicated. -- Miroslav Lichvar _______________________________________________ Linuxptp-devel mailing list Linuxptp-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/linuxptp-devel