On Mon, May 20, 2019 at 05:10:26PM +0200, Miroslav Lichvar wrote:
> error, except the nanosecond resolution. The NICs supported by the
> e1000e driver using ART for cross timestamping seem to be better than
> 1 microsecond and are possibly much better than that, but there
> doesn't seem to be any documentation that would explain how exactly it
> works and what would be the maximum error.

With cross timestamping and ART, you are using hardware time stamping,
so I would expect the error to be under 100 nanoseconds (or so).

@Jake, any insights on this point?

Thanks,
Richard



_______________________________________________
Linuxptp-users mailing list
Linuxptp-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/linuxptp-users

Reply via email to