Hello folks,

 I am using Mellanox Connect X5 dual port 100G card whose PTP clock devices (/dev/ptp0, /dev/ptp1) were synced using ptp4l and phc2sys via a PTP Appliance. We now install a KVM on the physical host and setup the Mellanox NIC as pass thru to the KVM. The KVM has the module ptp_kvm (/dev/ptp2) installed in it and i am able to successfully run phc2sys to sync /dev/ptp0 from /dev/ptp2 using the command

 phc2sys -O 35 -s /dev/ptp2 -c /dev/ptp0

NOTE: I am not using ptp4l inside the KVM since the ptp_kvm device gives the accurate time from the host that is already being synced using ptp4l/phc2sys on the host

But i am unable to provide an additional "-c" here to sync  the other ptp device in the KVM.

I know that is possible using the boundary clock config option in ptp4l  when we have ptp4l and phc2sys running in automatic mode since we had that working on the host without the KVM.

So any suggestions on how do i do phc2sys for multiple destination devices ?

--
cheers,

Hussam
(Hussamuddin Nasir)

Netlab, GENI & FABRIC Operations Team

-------------------------------------------------------------------
Laboratory for Adv. Networking  Phone  : (859)218-0059
James F Hardymon Building       Fax    : (859)323-3740
301 Rose Street, Rm 237         E-mail : na...@netlab.uky.edu
Lexington, KY 40506-0495        Web    : http://www.netlab.uky.edu

                        University of Kentucky
                        **********************
-------------------------------------------------------------------


_______________________________________________
Linuxptp-users mailing list
Linuxptp-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/linuxptp-users