On Wed, Aug 18, 2021 at 12:14:19PM +0000, Chang, Benjamin wrote: > I just wanted to follow up and see if there was any resource that > pointed out what each Parameter definition was for the PMC > management IDs. The resource I found only pointed out a handful.
The standardized messages exactly implement the 1588 standard, so please refer to that document. The custom message fields aren't documented, so you'll have to look at the source code. FWIW, you asked about TIME_STATUS_NP: master_offset 0 nanoseconds ingress_time 0 nanoseconds # For the next four, see "Follow_Up information TLV" from 802.1-AS cumulativeScaledRateOffset +0.000000000 scaledLastGmPhaseChange 0 gmTimeBaseIndicator 0 lastGmPhaseChange 0x0000'0000000000000000.0000 gmPresent false Boolean gmIdentity e89a8f.fffe.74f796 ClockIdentity HTH, Richard _______________________________________________ Linuxptp-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/linuxptp-users