> -----Original Message-----
> From: Federico Murciano <federico.murci...@dai-labor.de>
> Sent: Thursday, March 24, 2022 3:02 AM
> To: Keller, Jacob E <jacob.e.kel...@intel.com>; linuxptp-
> us...@lists.sourceforge.net
> Cc: Sebastian Peters <sebastian.pet...@dai-labor.de>
> Subject: AW: phc2sys not synchr. to right time and date
>
> Hi Jacob,
>
> Thank you for your answer. That is also what I thought, but the master and the
> slave are connected directly via an Ethernet Cable. Is it possible that the
> slave
> gets another Master clock from its second Ethernet interface, even if in the
> logs it
> says selected best master clock with the ID of my desired Master? See in the
> logs
> selected best master clock 04e548.fffe.230104:
>
And you've checked this master clock and it has the time you expect?
Are you feeding that time into the master clock networking device using phc2sys?
If you're using hardware timestamping, the clock on the device may not be in
sync with the gettimeofday clock.