On Mon, Jul 11, 2022 at 01:42:14AM +0000, joy_bhattacha...@arcadyan.com wrote:
> Slave is running ptp4l, GM is running custom time-sync solution > (G8275.1). GM has already been tested with Calnex Paragon Neo and > has passed the test so compliance with 1588 should not be the issue > here. How can it pass when sending incorrect values in the control field? > I have attached the 'Announce' messages from both CTL0 and > CTL5 tests. However, this issue is with linuxptp v3.1. Once we > change to master branch, this issue does not happen. Please bisect to find the offending commit. Thanks, Richard _______________________________________________ Linuxptp-users mailing list Linuxptp-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/linuxptp-users