If I don't do one per NIC how do devices connected to each different NIC do the PTP syncing? For instance, I have three LiDARs each with dedicated NIC and needing to receive the PTP time from this system in order to be properly sync'd to each other.
Some new information. Of the six NICs, enp0s31f6 that I was working with above is an I219-LM and the other five are I225-IT. The five I225-IT appear to be working as I had expected. I have no idea why the I219-LM is not working properly. I have stumbled upon this post: https://community.intel.com/t5/Ethernet-Products/Onboard-Intel-I219-LM-PTP-synchronization-problem-Driver-e1000e/td-p/1420598 which shows that others are also running into similar issues with the device and I've just posted there too. Please give it a read in case something stands out. Thanks, Josh Q On Tue, Jun 27, 2023 at 10:27 PM Richard Cochran <richardcoch...@gmail.com> wrote: > > On Mon, Jun 26, 2023 at 09:42:27AM -0400, engn...@gmail.com wrote: > > > Created /etc/systemd/system/phc2sys_<INTERFACE>.service for each of the > > above 6 ports > > I think you want just ONE instance of phc2sys running, not six. > > Thanks, > Richard _______________________________________________ Linuxptp-users mailing list Linuxptp-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/linuxptp-users