Hi guys, I'm having trouble with watchdog timeout - resitting to configure
a transparent firewall. Use this server between the core switch (catalyst)
and my core router (cisco). When I configure the bridge with the options
net.link.bridge.pfil_member: 1 and net.link.bridge.pfil_bridge: 1, the
system works properly, but use rules both in members and in bridges is
complex, the right would be to use only the bridge interface correct? When
I turn off the option net.link.bridge.pfil_member: 0, the interface
connected to the core switch begins to fall again and again with the
following error:

bce0: / usr / pfSensesrc / src / sys / dev / bce / if_bce.c (7273):
Watchdog timeout occurred, resetting!
bce0: link state changed to DOWN
bce0: link state changed to UP
bce0: / usr / pfSensesrc / src / sys / dev / bce / if_bce.c (7273):
Watchdog timeout occurred, resetting!
bce0: link state changed to DOWN
bce0: link state changed to UP
bce0: / usr / pfSensesrc / src / sys / dev / bce / if_bce.c (7273):
Watchdog timeout occurred, resetting!

I tried with other NICs as Realtek and Intel PRO 1000MT dual port and the
same thing happens, what could be this problem? I would only use
net.link.bridge.pfil_bridge: 1 and net.link.bridge.pfil_member: 0 because
it is simpler.
_______________________________________________
List mailing list
[email protected]
http://lists.pfsense.org/mailman/listinfo/list

Reply via email to