Merged,
Thanks,
Maxim.
On 06/10/15 11:09, Jerin Jacob wrote:
On Tue, Jun 09, 2015 at 08:26:28AM +0530, Jerin Jacob wrote:
ping.
otherwise "tt[i].tick" in "handle_tmo" will be a wrong value
in case timer set failed due to
ODP_TIMER_NOEVENT(failed to cancel the outstanding timer).
some hardware timer implementations needs at least two ticks gap between
"current tick" and "future tick" to cancel the outstanding active timer.
Signed-off-by: Jerin Jacob <[email protected]>
Reviewed-by: Ola Liljedahl <[email protected]>
---
v1: enclosed braces around the new "if" check as other if/else-branches use
braces
test/validation/odp_timer.c | 5 +++--
1 file changed, 3 insertions(+), 2 deletions(-)
diff --git a/test/validation/odp_timer.c b/test/validation/odp_timer.c
index 554b353..88f5208 100644
--- a/test/validation/odp_timer.c
+++ b/test/validation/odp_timer.c
@@ -365,9 +365,10 @@ static void *worker_entrypoint(void *arg TEST_UNUSED)
} else if (rc != ODP_TIMER_SUCCESS) {
/* Set/reset failed, timer already expired */
ntoolate++;
+ } else if (rc == ODP_TIMER_SUCCESS) {
+ /* Save expected expiration tick on success */
+ tt[i].tick = cur_tick + tck;
}
- /* Save expected expiration tick */
- tt[i].tick = cur_tick + tck;
}
struct timespec ts;
ts.tv_sec = 0;
--
2.1.0
_______________________________________________
lng-odp mailing list
[email protected]
https://lists.linaro.org/mailman/listinfo/lng-odp