On Wed, 17 Apr 2002 [EMAIL PROTECTED] wrote:

 > I'm still using 3.8.3 on my SOLARIS 7 machines, but I think this is more a
 > global kind of problem. I want to use the 'lpc redirect' command on a
 > queue that uses the application socket (Tectronix printer). My printcap
 > entry is:
 >
 > h01cp1t|1b_338_c_t|:\
 > ...
 >
 > Using the 'lpc' command generally works fine but the jobs never get to the
 > new destination queue becaus the IFHP filter tries to send them to the
 > printer itself. I always thought in case of a redirected printer the
 > filtering takes place in the final destination queue (?)

I have found that to get this to work (lprng 3.7.4), I need to specify
the server explicitely:

        lpc redirect printerA@printserver printerB@printserver

You might also need to restart lpd on the server.

-- 
Daniel E. Singer, System Administrator
Dept. of Computer Science, Duke University, Durham NC 27708 USA
        "Non cognosco. In hoc tantum laboro."


-----------------------------------------------------------------------------