On Wed, 17 Apr 2002 [EMAIL PROTECTED] wrote:
> I'm still using 3.8.3 on my SOLARIS 7 machines, but I think this is more a
> global kind of problem. I want to use the 'lpc redirect' command on a
> queue that uses the application socket (Tectronix printer). My printcap
> entry is:
>
> h01cp1t|1b_338_c_t|:\
> ...
>
> Using the 'lpc' command generally works fine but the jobs never get to the
> new destination queue becaus the IFHP filter tries to send them to the
> printer itself. I always thought in case of a redirected printer the
> filtering takes place in the final destination queue (?)
I have found that to get this to work (lprng 3.7.4), I need to specify
the server explicitely:
lpc redirect printerA@printserver printerB@printserver
You might also need to restart lpd on the server.
--
Daniel E. Singer, System Administrator
Dept. of Computer Science, Duke University, Durham NC 27708 USA
"Non cognosco. In hoc tantum laboro."
-----------------------------------------------------------------------------
YOU MUST BE A LIST MEMBER IN ORDER TO POST TO THE LPRNG MAILING LIST
The address you post from MUST be your subscription address
If you need help, send email to [EMAIL PROTECTED] (or lprng-requests
or lprng-digest-requests) with the word 'help' in the body. For the impatient,
to subscribe to a list with name LIST, send mail to [EMAIL PROTECTED]
with: | example:
subscribe LIST <mailaddr> | subscribe lprng-digest [EMAIL PROTECTED]
unsubscribe LIST <mailaddr> | unsubscribe lprng [EMAIL PROTECTED]
If you have major problems, send email to [EMAIL PROTECTED] with the word
LPRNGLIST in the SUBJECT line.
-----------------------------------------------------------------------------