On June 26, 2019 at 11:53:28 AM, Acee Lindem (acee) ([email protected]) wrote:
Acee:
Hi!
This may take a couple iterations. See inline.
I only have one response. :-)
....
....
3936 leaf dead-timer {
3937 type uint32;
3938 units "seconds";
3939 config false;
3940 description "This timer tracks the remaining time before
3941 the neighbor is declared dead.";
3942 }
[major] For *-timer: Is tracking the remaining time in seconds enough? I
would assume that ms would be the right unit. Why seconds?
<acee> Because sub-second hellos was a bad idea – three words: B-F-D…'
This question is not about sub-second Hellos…it’s about the *remaining
time*. Even if Hellos are x seconds apart, the “remaining time before the
neighbor is declared dead” can still be in ms, right? Why not? Note that
there are other places in the model that are characterized as tracking the
remaining time.
Thanks!!
Alvaro.
_______________________________________________
Lsr mailing list
[email protected]
https://www.ietf.org/mailman/listinfo/lsr