Ray,

I'm measuring the time to finish an image from next_inQ_item events - these occur when stageleader 0 picks up a new image from the input directory. I'm getting my fine-grained, per-stage looks at things based entirely by looking at them in NLV.

-Jon

Ray Plante wrote:
Jon,

What events are you using to time an image. Upon your recommendation (or maybe it was Robyn's), I'm using stageleader.main.MPI_Barrier1.{start,end}. Is this what you are using? It sounds like our numbers differ by 5-10 s per image.

My results are:
                            Time per image (s)
                       stage 0-4         stage 0-5
Consumerfull         82.8 +/- 1.9      138.5 +/- 3.1
Consumerless         12.6 +/- 1.9       15.7 +/- 2.3

cheers,
Ray