Ray,
I'm measuring the time to finish an image from next_inQ_item events -
these occur when stageleader 0 picks up a new image from the input
directory. I'm getting my fine-grained, per-stage looks at things based
entirely by looking at them in NLV.
-Jon
Ray Plante wrote:
Jon,
What events are you using to time an image. Upon your recommendation
(or maybe it was Robyn's), I'm using
stageleader.main.MPI_Barrier1.{start,end}. Is this what you are
using? It sounds like our numbers differ by 5-10 s per image.
My results are:
Time per image (s)
stage 0-4 stage 0-5
Consumerfull 82.8 +/- 1.9 138.5 +/- 3.1
Consumerless 12.6 +/- 1.9 15.7 +/- 2.3
cheers,
Ray