Hi, Cooper
I noticed that you added a check of platform which not defined
sa_sigaction in struct sigaction.
http://ltp.cvs.sourceforge.net/viewvc/ltp/ltp/testcases/kernel/syscalls/rt_sigaction/rt_sigaction01.c?r1=1.6&r2=1.7
As your expectted, the following message will output on x86_64.
------------
Your architecture doesn't support this test (no sa_sigaction field in struct
sigaction).
------------
But unfortunately, it still failed on my x86_64.
On my x86_64, signal.h like this:
------------
#ifndef __ASSEMBLY__
#ifdef __i386__
(sa_sigaction defined here) <--
#else /* __i386__ */
(no sa_sigaction defined) <--
#endif /* !__i386__ */
#endif /* __ASSEMBLY__ */
------------
your check still work ? Sorry, I don't know the check process in
LTP configure clearly. Could you give me some explanation.
Thank you very much.
--
Shi Weihua
------------------------------------------------------------------------------