Zamenjaj disk. D.
-- Uroš Golja pravi: > Pozdrav, > > za devetimi gorami in devetimi vodami ždi nek strežnik. V ta strežnik je > vtaknjen SATA krmilnik, ki uporablja linuxov gonilnik sata_sil24 > (Silicon Image, Inc. SiI 3124 PCI-X Serial ATA Controller (rev 01)). Na > gonilnik so pripeti trije enaki Maxtorjevi diski po 200 GB. Nad temi > tremi diski teče linuxov md array /dev/md0 v načinu RAID5. > > Zadnje čase se je začelo dogajati tole: > [EMAIL PROTECTED] 07:41:43 ~ > # cat /var/log/kern.log > [snip] > Sep 26 19:00:52 floki kernel: ata2: exception Emask 0x10 SAct 0x0 SErr > 0x80000 action 0x2 frozen > Sep 26 19:00:52 floki kernel: ata2: (irq_stat 0x01100010, PHY RDY changed) > Sep 26 19:00:53 floki kernel: ata2: soft resetting port > Sep 26 19:01:03 floki kernel: ata2: softreset failed (timeout) > Sep 26 19:01:03 floki kernel: ata2: hard resetting port > Sep 26 19:01:08 floki kernel: ata2: hardreset failed (PHY debouncing failed) > Sep 26 19:01:08 floki kernel: ata2: reset failed (errno=-5), retrying in > 5 secs > Sep 26 19:01:13 floki kernel: ata2: hard resetting port > Sep 26 19:01:19 floki kernel: ata2: hardreset failed (PHY debouncing failed) > Sep 26 19:01:19 floki kernel: ata2: reset failed (errno=-5), retrying in > 30 secs > Sep 26 19:01:48 floki kernel: ata2: hard resetting port > Sep 26 19:01:53 floki kernel: ata2: hardreset failed (PHY debouncing failed) > Sep 26 19:01:53 floki kernel: ata2: reset failed, giving up > Sep 26 19:01:53 floki kernel: ata2.00: disabled > Sep 26 19:01:53 floki kernel: ata2: EH complete > Sep 26 23:50:46 floki kernel: sd 1:0:0:0: [sdb] Result: > hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK,SUGGEST_OK > Sep 26 23:50:46 floki kernel: end_request: I/O error, dev sdb, sector > 61284415 > Sep 26 23:50:46 floki kernel: sd 1:0:0:0: [sdb] Result: > hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK,SUGGEST_OK > Sep 26 23:50:46 floki kernel: end_request: I/O error, dev sdb, sector > 61284415 > Sep 26 23:50:46 floki kernel: raid5: Disk failure on sdb1, disabling > device. Operation continuing on 2 devices > Sep 26 23:50:46 floki kernel: RAID5 conf printout: > Sep 26 23:50:46 floki kernel: --- rd:3 wd:2 > Sep 26 23:50:46 floki kernel: disk 0, o:1, dev:sda1 > Sep 26 23:50:46 floki kernel: disk 1, o:0, dev:sdb1 > Sep 26 23:50:46 floki kernel: disk 2, o:1, dev:sdc1 > Sep 26 23:50:46 floki kernel: RAID5 conf printout: > Sep 26 23:50:46 floki kernel: --- rd:3 wd:2 > Sep 26 23:50:46 floki kernel: disk 0, o:1, dev:sda1 > Sep 26 23:50:46 floki kernel: disk 2, o:1, dev:sdc1 > [snip] > > Array je zelo malo obremenjen, napaka se vedno pojavi med delovanjem. > Disk odleti dobesedno med "idlanjem". Vedno gre za isti disk. Zamenjal > sem krmilnik (prej je bil notri Sil 3114). Diske sem priključil na druge > porte na krmilniku. Ista stvar. Nato sem posumil, da bi lahko bil disk > fuč. Vklopljen imam SMART, vendar smartctl --all /dev/sdb ne pokaže, da > bi bilo z njim kaj narobe. Statistike so precej enake kot na ostalih > dveh diskih. > > Ima kdo kakšno idejo, preden grem zamenjat ves hardver do zadnjega SATA > kabla? Strežnik je, čeprav izrazito neobremenjen, vseeno zelo pomemben. > > LP, > U. > _______________________________________________ > lugos-list mailing list > [email protected] > http://liste2.lugos.si/cgi-bin/mailman/listinfo/lugos-list _______________________________________________ lugos-list mailing list [email protected] http://liste2.lugos.si/cgi-bin/mailman/listinfo/lugos-list
