So here are the new numbers when using a 1K IB MTU.

                 __1MB_MTU_!FMR__        __1MB_MTU_+FMR__     

                 VIB  O2IB  Ratio        VIB  O2IB  Ratio 

Writes MB/s      679   680  100 %        579   585   101 %
Reads MB/s       659   663  101 %        567   579   102 %

I redid all measurements (were 2 different nodes, may explain slight diff with
initial figures)

So OFED-1.1 now always  performs at least as good as VIB. Good news.

I am still not happy with the way to fix this IB MTU issues by the way.
Right now I have a modparam to force the MTU.

But since it may be either the active or passive node that has a 23108 board,
there should be a better way to negotiate the MTU. Using the SM is a problem,
since there are multiple flavors of SMs.

We also still have a fair peformance drop when going to FMR, but this hasn't
changed as compared to VIB and is a different story.

                !FMR      +FMR    
                   
Writes MB/s      680       585   86 %
Reads MB/s       663       579   87 %

_______________________________________________