On Wed, Dec 25, 2013 at 01:45:24PM +0900, KATOH Yasufumi wrote:
> patch /etc/inittab in plamo container to shutdown when it receives SIGPWR.
> (By default, plamo shutdowns to single user mode after 5minutes)
> 
> Signed-off-by: KATOH Yasufumi <[email protected]>

Acked-by: Stéphane Graber <[email protected]>

> ---
>  templates/lxc-plamo.in | 6 ++++++
>  1 file changed, 6 insertions(+)
> 
> diff --git a/templates/lxc-plamo.in b/templates/lxc-plamo.in
> index b133da3..485f363 100644
> --- a/templates/lxc-plamo.in
> +++ b/templates/lxc-plamo.in
> @@ -178,6 +178,12 @@ configure_plamo() {
>       EOF
>    # /etc/inittab
>    cat <<- "EOF" | patch $rootfs/etc/inittab
> +     32,33c32,33
> +     < # What to do when power fails (shutdown to single user).
> +     < pf::powerfail:/sbin/shutdown -f +5 "THE POWER IS FAILING"
> +     ---
> +     > # What to do when power fails (shutdown).
> +     > pf::powerfail:/sbin/shutdown -h +0 "THE POWER IS FAILING"
>       47a48
>       > 1:1235:respawn:/sbin/agetty 38400 console
>       52,53d52
> -- 
> 1.8.4.4
> 
> _______________________________________________
> lxc-devel mailing list
> [email protected]
> http://lists.linuxcontainers.org/listinfo/lxc-devel

-- 