Hello, In going through the code for hal_temp_bbb.py there are default settings for the function of the ADD in lines 169 - 174 that specifiy:
n = Hal component name i = ADC update interval (default = 0.05) c = Number of channels f = filter size (default = 10) b = Type of cape used. These are then called loadusr -Wn Therm hal_temp_bbb -n Therm -c 04:epcos_B57560G1104,05:epcos_B57560G1104 -b CRAMPS But there is no setting for either *i* or *f*. This was not present in the old readtemp.py So, can these default settings cause a problem in the ADC that causes it to hang or lockup if you go with the default distribution ? What do others do who happen to use the CRAMPS board ? Any takers ? -- website: http://www.machinekit.io blog: http://blog.machinekit.io github: https://github.com/machinekit --- You received this message because you are subscribed to the Google Groups "Machinekit" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. Visit this group at https://groups.google.com/group/machinekit. For more options, visit https://groups.google.com/d/optout.