>  Anyway, attached is a serpentine Floyd-Steinberg implementation.

The mailing list does not accept attachments, instead e-mail it directly
to this address.

ImageMagick was originally based on a Floyd-Steinberg implementation
but in our testing we found the Hilbert curve method gave a more
visually pleasing result among a set of test images when we compared
the two methods.  Our testing method was to present a set of 25 images
side by side (one the original and one dithered with either Hilbert
or Floyd-Steinberg).  The Hilbert dithering was choosen a majority of
the time.  Its been about 10 years, so we will revisit the issue when
we receive your patch.