In the second line of workspace MI places version number, which aborts the
reading by earlier versions.  Also, the MI 5 and up versions sometimes writes
printer driver information into workspaces, which older versions can't process.
    So, to fix your problem, open the workspaces in text editor and replace
!Version 550
with
!Version 450
and see it that does the trick. If it does not,  go to the end of workspace and
delete printer driver info. It should be in the last couple of lines.
Enjoy.
--
Sonya Nikolsky

JCH GeoInfo
3600 University Dr
Durham NC 27707


Cattaneo Pietro BRP wrote:

> Hi everybody
>
> We've got a big trouble with MI and I hope someone can help me.
>
> We have got many user of MI in our office. To test MI 5.5 we installed once
> the new version.
> With MI 5.5 we opened older Workspaces, witch we saved with MI 4.5.
> Now, if we make changes with MI 5.5 to the workspaces we did with MI 4.5, we
> can't open the new Workspaces with MI 4.5 anymore.
> Can anyone tell me, if there is a solution for this problem.
>
> Thanks a lot
>
> Pietro Cattaneo
>
> Pietro Cattaneo
> Bundesamt f�r Raumplanung
> Sektion Infrastruktur
> Einsteinstrasse 2
> CH-3003 Bern
> Tel.: ++41 (0)31 324 14 48
> Fax.: ++41 (0)31 322 78 69
> E-Mail:  <[EMAIL PROTECTED]> [EMAIL PROTECTED]
>
>  <http://www.brp.admin.ch/> http://www.brp.admin.ch/
>
> ----------------------------------------------------------------------
> To unsubscribe from this list, send e-mail to [EMAIL PROTECTED] and put
> "unsubscribe MAPINFO-L" in the message body, or contact [EMAIL PROTECTED]



----------------------------------------------------------------------
To unsubscribe from this list, send e-mail to [EMAIL PROTECTED] and put
"unsubscribe MAPINFO-L" in the message body, or contact [EMAIL PROTECTED]

Reply via email to