On 15.04.15 15:26, [email protected] wrote:
revision-id: eb47b226d268e7820a9153672798cf991a8fd0fa
parent(s): cc84ac3be41d9d6ac480d55449d5bf4e324cca10
committer: Vicențiu Ciorbaru
branch nick: server
timestamp: 2015-04-15 16:23:43 +0300
message:

MDEV-7820 Server crashes in in my_strcasecmp_utf8 on subquery in ORDER BY 
clause of GROUP_CONCAT

It is possible for Item_field to have a NULL field_name. This is true if
the Item_field is created based on a field in a temporary table that has
no name. It is thus necessary to do a null check before attempting a
strcmp.

Thank you. OK to push. (do not forget to run full test suite)

[skip]

_______________________________________________
Mailing list: https://launchpad.net/~maria-developers
Post to     : [email protected]
Unsubscribe : https://launchpad.net/~maria-developers
More help   : https://help.launchpad.net/ListHelp

Reply via email to