<http://www.wickedlocal.com/arlington/features/x1700903693/Appleton-Street-fire?foto=1>
That is C2 in white - so this picture was taken afetr all of the first alarm companys had arrived. Arlington Mass - April 6, 2011 1817 - box transmitted (911 call probably received at 1816) 1819 - E3 at scene (the quint) 1820 - E2 to E3 - need a feeder? 1821 - C2 at scene 1822 - E2 is dropping a line So it probably took 5 minutes to get a feeder from the hydrant to the Quint. If the Quint only has 400 gallons of water, then maybe they ran out of water before the hydrant line was connected in. This is a trade off to be considered with Quints. If they have smaller water tanks - then a Quint might run out of water 1 minute faster than a pumper with 500 gallons - or 3 minutes faster than a pumper with a 750 gallon tank -- You received this message because you are subscribed to the Google Groups "massfire" group. To post to this group, send email to [email protected]. To unsubscribe from this group, send email to [email protected]. For more options, visit this group at http://groups.google.com/group/massfire?hl=en.