> On 16 Jan 2017, at 19:23, Gert Doering <[email protected]> wrote:
> 
> On Mon, Jan 16, 2017 at 10:11:22AM +0100, Mirjam Kuehne wrote:
>> https://labs.ripe.net/Members/stephen_strowes/reviewing-the-2016-leap-second
> 
> I find the statement
> 
> "While many of our RIPE Atlas anchors are configured to skew time back 
> towards UTC when a change is detected (as above), some of the older anchors 
> are configured to observe the leap indicator in NTP responses and respond to 
> it by stepping system clocks backwards"
> 
> quite interesting.  
> 
> Do not all anchors run the same software?  If not, why not?


The NTP daemons on the v1 and the v2 anchors are configured differently. The 
difference wasn’t intentional, but it did provide us with an interesting 
comparison!

S.