Thanks a lot Dr. Ray for your kind advise. Hoping for same in future 
also.KDSinghOn Fri, 21 Mar 2008 10:47:30 -0400 "MATPOWER discussion forum" 
wroteIt only means that it did not converge in the default number of 
iterations. It may be that the problem is infeasible. You can try increasing 
the number of iterations via ...opt = mpoption('VERBOSE', 2, 'CONSTR_MAX_IT', 
250);runopf('yourcase', opt);Also, when creating a new case, it is always a 
good idea to make sure that you can successfully solve a power flow, before 
attempting an OPF, but without more information it is impossible to know what 
is happening in your case.-- Ray ZimmermanSenior Research Associate428-B 
Phillips Hall, Cornell University, Ithaca, NY 14853phone: (607) 255-9645 On Mar 
21, 2008, at 8:12 AM, kanwardeep singh wrote:Dear Sir,Thanks for your response 
to my earlier querry. I have been facing a problem that when I tried to run a 
separate OPF program for a case of 6 buses, using 'fmincon' , a message is 
displayed on command window as follows:Maximum number of function evaluations 
exceeded; increase OPTIONS.MaxFunEvals.Please help me that where I am 
wrong.KDSingh

Reply via email to