To make use of them properly requires implementing a full unit-commitment algorithm. I spent a few minutes thinking about it and I don't think there is a way to easily add these into uopf, since it really is just a de-commitment heuristic. You could extend it to include the shutdown costs, but adding the possibility of turning on units that are initially off requires a more complete treatment of the unit commitment problem.
-- Ray Zimmerman Senior Research Associate 211 Warren Hall, Cornell University, Ithaca, NY 14853 phone: (607) 255-9645 On Jun 10, 2011, at 5:33 PM, Colunga, Richard Anthony wrote: > Hello, > > I understand that the start up and shut down costs are not used by any of the > algorithms in MATPOWER. What instructions should be added to include these > values and where should these instructions be placed when running uopf? >