I don't really have a flow-chart, but flow is pretty linear. Here are the basic steps that are performed when calling runopf …
- load data into mpc data struct - convert data to internal numbering, remove out-of-service equipment - construct matrices and vectors needed to formulate OPF problem (Ybus, variable bounds, costs, etc.) - build OPF model object, with all variable and constraint indexing info - call the selected solver (each has it's own algorithm) - package results in the results struct - convert results back to external numbering, add back out-of-service equipment - optionally print and/or save results Hope this helps, -- Ray Zimmerman Senior Research Associate 419A Warren Hall, Cornell University, Ithaca, NY 14853 phone: (607) 255-9645 On Jan 30, 2013, at 9:37 AM, dian anggun trisnadi <[email protected]> wrote: > i trying to understand how runopf on Matpower work, then i searching for flow > chart on internet, but i don't get any > can anyone give me the flow chart? > > regards, Dian