Dear Shri,
I am running an ACOPF not a simple power flow. When I set in the mpc.gen matrix
thatPg= Pmax=Pmin and Qg=Qman=Qmin (ie the corresponding columns having the
same value)and then runopf ('caseExample') then , matpower ignores this
constraint, ie that pmax=pmin=pg.Are you sure it works for you?
IS there a way for this Dr Zimmerman?
Thank you
Subject: Re: Constraining matpower
From: [email protected]
Date: Mon, 20 May 2013 08:47:09 -0500
To: [email protected]
Setting Pgmax=Pgmin=Pg (similarly for Qg) should constrain the generator output
to a fixed value.
Shri
On May 20, 2013, at 8:01 AM, spyros gian <[email protected]> wrote:
Dear Dr Zimmerman,
I have solved an ACOPF in an optimisation tool. I would like to get the
solutions from this tool, and plug them to the matpower.In particular, I want
to get the solutions for the Pgeneration and Qgeneration for each generator
that the optimisation tool gave me,and plug them into matpower.
This will allow me to see whether the matpower gives the same values for
voltage magnitudes that I got.
Should I program some code in matlab so that i constrain matpower's mpc.gen
matrix to have these values?
I guess that if i put these values to the columns Pg,Qg of the matpower mpc.gen
matrix, this will not constrain matpower.
Thank you for your insight
Syros Giannakos