MATPOWER does not include ramp rate in power flow analysis. Power flow finds a steady state solution, whereas ramp rate has to do with changes in solution through time (e.g. limiting differences between two steady state solutions). So I don't really think ramp rate is relevant to the traditional power flow problem.
-- Ray Zimmerman Senior Research Associate B30 Warren Hall, Cornell University, Ithaca, NY 14853 phone: (607) 255-9645 On Jun 10, 2013, at 1:08 PM, Jiashen Teh <[email protected]> wrote: > Dear Dr Ray, > > May I know , does Matpower includes Ramp rate in its generator during power > flow analysis. > > If it does not, may I know how would you do it if you were to include those? > > Many thanks in advance > > Yours sincerely, > > Jiashen Teh > PhD Student > Electrical Energy & Power Systems Group, School of Electrical & Electronic > Engineering > Ferranti Building (B18), The University of Manchester, M13 9PL, United Kingdom > Tel: +44 (0) 161 306 2263; Mobile: +44 (0) 792 322 4864