Dr. Ray Zimmerman, in order to clear up the generator limits, in the mpc.gen matrix , when we have P<=Pmax and Q<=Qmax, this is a 'box' constraint as the manual says i.e. it only means P<=Pmax, and Q<=Qmax i.e. at the same time we can have Pgen=Pmax and Qgen=Qmax. Correct? Thank you
________________________________ From: Ray Zimmerman <[email protected]> To: MATPOWER discussion forum <[email protected]> Sent: Thursday, August 1, 2013 2:35 PM Subject: Re: Generation per generator and not per bus See Table C-3 in the User's Manual. Set OUT_GEN to 1. -- Ray Zimmerman Senior Research Associate B30 Warren Hall, Cornell University, Ithaca, NY 14853 phone: (607) 255-9645 On Aug 1, 2013, at 8:57 AM, spyros gian <[email protected]> wrote: Dr Zimmerman, > >Matpower shows the Generation per bus, and not per generator. >I have a multi-bus system, and some buses have 3-4 generators. >How can I show the generation per generator? > > > > > > > > > >