Hi Ray , Thanks for the reply.
With Regards Nair On Fri, Feb 6, 2015 at 1:54 PM, Ray Zimmerman <[email protected]> wrote: > Currently MATPOWER only handles constant power loads. You could > technically model a constant impedance load as well by putting the > appropriate values in the GS and BS columns of the bus matrix, but these > are not explicitly reported as loads, so you would have to manually compute > the corresponding power draw at the solution. > > Ray > > > > On Feb 6, 2015, at 3:25 PM, arun s nair <[email protected]> wrote: > > > > Hi > > > > I am trying to study the behavior of different kinds of loads on buses. > > > > Is there anyway in Matpower by which I can try different type of load > models like a ZIP load model,Voltage dependent loads ,Exponential load etc > on a bus to study the variations? > > > > (I have read that in the cpf method we use just constant power loads, is > there a way I can do the same with a different load?) > > > > Thanking in advance > > > > With Regards > > > > Nair > > > >