Hi Ray ,

Thanks for the reply.

With Regards

Nair

On Fri, Feb 6, 2015 at 1:54 PM, Ray Zimmerman <[email protected]> wrote:

> Currently MATPOWER only handles constant power loads. You could
> technically model a constant impedance load as well by putting the
> appropriate values in the GS and BS columns of the bus matrix, but these
> are not explicitly reported as loads, so you would have to manually compute
> the corresponding power draw at the solution.
>
>    Ray
>
>
> > On Feb 6, 2015, at 3:25 PM, arun s nair <[email protected]> wrote:
> >
> > Hi
> >
> > I am trying to study the behavior of different kinds of loads on buses.
> >
> > Is there anyway in Matpower by which I can try different type of load
> models like a ZIP load model,Voltage dependent loads ,Exponential load etc
> on a bus to study the variations?
> >
> > (I have read that in the cpf method we use just constant power loads, is
> there a way I can do the same with a different load?)
> >
> > Thanking in advance
> >
> > With Regards
> >
> > Nair
>
>
>
>

Reply via email to