See section 6.4.2 on ‘dispatchable loads’ in the MATPOWER manual.

Shri

From: Mahdi Kiaee <meh19...@yahoo.com<mailto:meh19...@yahoo.com>>
Reply-To: MATPOWER discussion forum 
<matpowe...@list.cornell.edu<mailto:matpowe...@list.cornell.edu>>
Date: Friday, August 21, 2015 at 1:35 PM
To: "MATPOWER-L@cornell.edu<mailto:MATPOWER-L@cornell.edu>" 
<MATPOWER-L@cornell.edu<mailto:MATPOWER-L@cornell.edu>>
Subject: Add a load as a variable to the extended optimal power

Hi there,
I have got a question regarding the extended optimal power flow feature in 
MATPOWER. Is there any way to add a variable to the extended optimal power flow 
while that variable is the load of a bus on the power system at the same time? 
In other words, I want the load of a bus to be considered as an optimisation 
variable.
Thank you in advance.
Mahdi