Hi Wenlei,

Try this instead:

runpf('case33bw', mpoption('pf.alg', 'PQSUM'))

The radial_pf() function is not meant to be called directly by the user, since 
it requires that the case be converted to internal bus numbering first. It is 
called by runpf() which does that conversion for you.

   Ray


> On May 31, 2017, at 7:59 PM, Bai, Wenlei <[email protected]> wrote:
> 
> Dear Ray, 
> When I used 'radial_pf' to run a distribution case load flow, it gave me 
> error as the following:
> Could you take a look?  Thank you
> 
> Wenlei
> <pastedImage.png>
> Wenlei Bai
> Electrical Engineering, Department of Electrical & Computer Engineering
> Baylor University, One Bear Place #97356
> Waco, TX 76798-7356 
> (254)405-3320
> [email protected] <mailto:[email protected]>

Reply via email to