MOST handles stochastic DC OPF. See Section 7.1.4 in the MOST User’s Manual
<http://www.pserc.cornell.edu/matpower/docs/MOST-manual-1.0.pdf>. MATPOWER does
not have capabilities for probabilistic AC power flow or AC OPF.
Ray
> On Apr 15, 2018, at 4:40 AM, Данил Игнатьев <[email protected]>
> wrote:
>
> Dear Sirs,
>
> I'm interested to know whether there is an option to carry out Probabilistic
> Power Flow calculation in the current Matpower version or in the versions
> under development?
>
>
> Yours faithfully,
>
> Danil Ignatiev
>
>
> [email protected]
>