In MATPOWER, the APF column of the gen matrix refers to the area participation factor associated with AGC for a given control area, but it is not currently used by any of MATPOWER’s routines (runpf, runcpf, or runopf), though there is a proposal <https://github.com/MATPOWER/matpower/issues/63> to use it (if specified) to determine how to distribute the slack across multiple generators at the slack bus.
Ray > On Mar 13, 2019, at 10:17 AM, Jubeyer Rahman <[email protected]> wrote: > > So, can you please tell me how the current APF data in generator section is > being used? I don't see much discussion on that in the document. or Can you > at least any reference which discusses about it? > > I have found one thread regarding APF, posted a long time ago(2012), is there > any progress on that? > > https://www.mail-archive.com/[email protected]/msg02004.html > <https://www.mail-archive.com/[email protected]/msg02004.html> > > > Regards, > Jubeyer > > On Mon, Mar 11, 2019 at 9:47 AM Ray Zimmerman <[email protected] > <mailto:[email protected]>> wrote: > To do this, you would have to introduce your own user-defined constraint on > the generator dispatch proportions. > > Ray > > > > On Mar 5, 2019, at 3:50 PM, Jubeyer Rahman <[email protected] > > <mailto:[email protected]>> wrote: > > > > Hi, > > Does anyone know if there is a way in matpower to make the generators > > respond as per their participation factor while running the optimal power > > flow confirming the generations are within the predefined limit? > > > > Regards, > > Jubeyer > > > > > > > > > > >