MATPOWER does not have any implementation of L-index functionality. And your other question about modeling wind generation is addressed in my previous response below. Feel free to get more specific with your question if there is a specific part you don’t understand.
Ray > On Nov 10, 2019, at 12:35 AM, zafar ayub <[email protected]> wrote: > > Hi Ray, Hope this mail will find you well. Can we model L-index in Matpower , > if yes then plz share the information > Thank you > Ayub > > On Tue, Oct 29, 2019, 8:41 PM Ray Zimmerman <[email protected] > <mailto:[email protected]>> wrote: > For a simple power flow or OPF, you can model a wind generator as any other > generator (specify the output power) or as a negative load. For the OPF, you > might consider setting the cost to a level below which the wind generation > would be curtailed. > > Ray > > > > On Oct 28, 2019, at 2:01 AM, zafar ayub <[email protected] > > <mailto:[email protected]>> wrote: > > > > Hi Matpower, > > hope u all will be ok and good. > > i want to know, how can i integrate wind power to the existing power system > > IEEE any standard bus system in matpower. > > thank you > > very much' > > Zafar Ayub > > >