|
Carlos Ferrandon Cervantes wrote:
Hello everyone:
I’ve been working quite a while with a UC problem
in MOST, using the IEEE RTS. I realised that when I compare the
mdo.UC.CommitSched results with mdo.results.ExpectedDispatch
there are differences in the commitment status and real power
output. This happens only with machines with zero starting cost
in my system. i.e. hydro and wind. Say for example, I have a
commitment status of 1, but a power output of 0 for certain
machine. In some cases, i have six hydro units In a bus, and
there could be differences in three of them. It might be a dumb
question, but do you have an idea why this could be happening ?
or how should I interpret this results?
Thank you so much in advance and stay safe,
Carlos
--
Carlos:
I've had this happen if, for example, I forget to add some kind of
sensible RAMP_30 number for a unit. A zero there
might produce this behavior.
Carlos.
|