Sorry for the delay; just got my computer back after six days in repair.
Matt followed up,
| With a JE520 in "-AD" monitor mode (no disc in it)
| It is resamplaing 32Khz & 48Khz inputs to 44.1Khz for its digital
| output.
Right.
| Will not output a 96Khz input signal.
OK.
| Also using a 44.1Khz input to the 520, with a Level 1 +/- 50ppm clock
| accuracy it's outputting
| 44.1Khz with a Level II +/- 1000ppm clock accuracy, along with adding
| the MD category code, changing the SCMS status etc..
As to resampling 44.1 to 44.1: hmm.
As to changing the category code, yes, I've seen that myself.
As to changing the SCMS status: HUH? In my experience it does not.
| When in Record pause or recording (with a disc in the deck)
| The Input is been passed to the output without anything been changed.
| 96Khz signal is been passed through (output is 96Khz)
Interesting, since it can't handle that signal itself.
| The clock is that from the input
OK.
| Category code doesn't change to MD, SCMS is the same etc....
That jibes with my experience.
Thanks for clearing that up, Matt.
-----------------------------------------------------------------
To stop getting this list send a message containing just the word
"unsubscribe" to [EMAIL PROTECTED]