Hi,

 

I just want to double-check my understanding of PortMIDI's approach to
SysEx:

 

1.        The first and last PmEvents received as part of a SysEx message
will have their status bytes set to f0 and f7, respectively and can be
treated as 3-byte messages if the time-stamp isn't required;

2.       Any PmEvents containing SysEx data, except as described above, use
all four bytes of a PmEvent, so the time stamp byte becomes just another
data byte.

 

Best wishes.

 

Tim Burgess