All messages should be posted in plain text. HTML will be converted to attachments. The meditech-l web site is MTUsers.com ======================================
We are Magic but have the same type issue. What we have done to work around this is create combination orders for every possible combination CT. (Pain in the butt, but not sure how to make it work any other way) Our PACS (Amicas) does not allow splitting a study after being sent. So we have orders for Abd/Pel, Chest/Abd/Pel, etc. This allows multiple studies to have one accession number. If everything seems to be going well, you have obviously overlooked something. Bill Suggs, RT (R) PACS Administrator Newman Regional Health Emporia, KS 66801 (620) 341-7893 -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of McCarthy, Lori Sent: Wednesday, March 29, 2006 11:47 AM To: Kathryn Wohnoutka; Meditech-L (E-mail) Subject: RE: [MEDITECH-L] Client Server: CT Image Storage in PACS All messages should be posted in plain text. HTML will be converted to attachments. The meditech-l web site is MTUsers.com ====================================== Kathryn, In your PACS software, can you assign a new study UID to the PELVIS images, then resolve them to the PELVIS order/ascession#? Lori McCarthy Central Vermont Medical Center (802) 371-4447 -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Kathryn Wohnoutka Sent: Tuesday, March 28, 2006 3:46 PM To: Meditech-L (E-mail); CSListServ (E-mail) Subject: [MEDITECH-L] Client Server: CT Image Storage in PACS All messages should be posted in plain text. HTML will be converted to attachments. The meditech-l web site is MTUsers.com ====================================== We have a radiologist who's concerned about the way CT images are currently being stored in our PACS. Today we get orders/requisitions through MT and then this information is pulled to CT worklist and then that information is transferred to PACS when the study is completed. The problem in CT is a timing issue with our IV contrast agent and the way studies are done simultaneously (CT chest, abdomen, and pelvis) for instance. Because of the contrast we cannot stop doing the chest switch to the abdomen information in the worklist and then switch to the pelvis information, but when all of this transfers to PACS it appears as one study (whichever information is pulled from worklist) most likely CT chest in this instance. He's concerned that some studies may appear to have not been done by looking at the PACS. Thank you in advance for your help, Katie Kathryn Wohnoutka PCS/EDM/ITS/OR Applications IS Specialist Citizens Memorial Healthcare 1500 N. Oakland Bolivar, Missouri 65613 phone: 417-328-6609 fax: 417-777-7157 pager: 800-801-2988 [EMAIL PROTECTED] The information contained in this e-mail, including any attachments,is legally privileged and confidential. If you are not the intended recipient, you are hereby notified that any use or dissemination of this message is strictly prohibited. If you have received this message in error, please immediately notify us by telephone 417-328-6526 and delete this message from your system. Even though this e-mail and any attachments are believed to be free of any virus or other defect that might affect any computer system into which it is received and opened, it is the responsibility of the recipient to ensure that it is virus free, and no responsibility is accepted by Citizens Memorial Hospital for any loss or damage arising in any way from its use. _______________________________________________ meditech-l mailing list [email protected] http://mtusers.com/mailman/listinfo/meditech-l _______________________________________________ meditech-l mailing list [email protected] http://mtusers.com/mailman/listinfo/meditech-l _______________________________________________ meditech-l mailing list [email protected] http://mtusers.com/mailman/listinfo/meditech-l