All messages should be posted in plain text. HTML will be converted to attachments. The meditech-l web site is MTUsers.com ======================================
Thanks Brian. I picked up this report at last year's regional MUSE and I use it often. Thanks for sharing with the list!
Alan R. Baillargeon RN, BSN
Senior Clinical Analyst
Information Systems
(410) 620-3464
Pager (410) 378-0171
Note: This message and any attachments are intended only for the use of the individual or
entity to which it is addressed and may contain information that is privileged,
confidential, and exempt from disclosure under applicable law. If the reader of this
message is not the intended recipient, or the employee or agent responsible for delivering
the message to the intended recipient, you are hereby notified that any dissemination,
distribution or copying of this communication is strictly prohibited. If you have received
this communication in error, please notify the sender.
| "Brian Schmit"
<[EMAIL PROTECTED]>
Sent by: [EMAIL PROTECTED] 07/18/2006 04:31 PM |
|
All messages should be posted in plain text. HTML will be converted to
attachments. The meditech-l web site is MTUsers.com
======================================
Hi Renee,
You can use the attached report to figure out the ASCII code for any keystroke, including a tab. The name of the report is MIS.USER.zcus.picis.bms.keyboard. When running it, you can press any keystroke and the ASCII character will appear in the upper-left-hand corner of the screen.
Please let me know if you have any questions.
Good luck,
Brian Schmit
Sr. Programmer, Picis
Direct: 781 557 3315
Fax: 781 557 3140
100 Quannapowitt Parkway
Suite 405
Wakefield, MA 01880
[EMAIL PROTECTED]
www.picis.com
Please visit http://www.picis.com/services/technical/npr.asp# for additional information about our NPR Report Writing Trainings.
The information in this email is confidential and may be legally privileged. It is intended solely for the addressee. Access or use by any other person to this internet email is not authorized and may be unlawful. If you are not the intended recipient, please delete or destroy this email. If you do not wish to receive future emails from the sender, please reply directly to this email requesting you be removed from any mailing list.
-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] Behalf Of Renee Rinehart
Sent: Friday, July 14, 2006 2:17 PM
To: [email protected]
Subject: [MEDITECH-L] field delimiter help
All messages should be posted in plain text. HTML will be converted to
attachments. The meditech-l web site is MTUsers.com
======================================
What field delimiter do I use for a tab delimited report? Thanks.
Renee' Rinehart, HCIS Financial Coordinator
Guadalupe Regional Medical Center
Seguin, Texas 78155
830-401-7214
[EMAIL PROTECTED]
_______________________________________________
meditech-l mailing list
[email protected]
http://mtusers.com/mailman/listinfo/meditech-l
_______________________________________________
meditech-l mailing list
[email protected]
http://mtusers.com/mailman/listinfo/meditech-l
MEDITECH.CUST.RPTS^Newton-Wellesley
Hospital^NEW5.4^TEST.5.4.MIS^MSM.BMS^20060718^A^ASCII Code report by Brian
Schmit of Picis
MIS.USER.zcus.picis.bms.keyboard
PROC
MIS.USER.zcus.picis.bms.keyboard
[EMAIL PROTECTED]
MACRO
MIS.USER.zcus.picis.bms.keyboard.M.s
0
IF{/DONE;
1
1^/DONE^/R.FRAGMENT^/Z.SCHED.LOG,
2
1},
3
"PRESS KEY FOR ASCII CODE OR <ESC> TO EXIT";
MACRO
MIS.USER.zcus.picis.bms.keyboard.M.start.macro
0
@Cursor.off("")^#,
1
DO{E(#S^Y)^X'[EMAIL PROTECTED] @Pos(0,46,Y:0X:3L)[EMAIL PROTECTED](0,0,X:3L)^#},
2
@W.return("ASCII code for <Esc> is "_X_". Press <Enter> please."),
3
@Cursor.on("")^#
RPT
Yzcus.picis.bms.keyboardMIS.USER ,"_%MIS.USER.zcus.picis.bms.keyboard.M.s(0)_"REG1292660 66 NNNYN 01 1Y
AT 757614478
MSM.BMSE
AT 760122707
MSM.BMSE
AT 777142676
MSM.BMSE
AT 798646616
MSM.BMSE
AT 798821004
MSM.BMSE
AT 806771972
MSM.BMSE
AT 817467207
MSM.BMSE
AT 832523014
MSM.BMSE
CI
DC1
This report was created by Brian Schmit of Picis
DC2
DC3
Contact Information: Brian Schmit
DC4
Sr. Programmer, Picis
DC5
Direct: 781 557 3315
DC6
Fax: 781 557 3140
DC7
100 Quannapowitt Parkway
DC8
Suite 405
DC9
Wakefield, MA 01880
DC10
[EMAIL PROTECTED]
DC11
www.picis.com
DC12
DC13
Picis provides trainings for NPR Report Writer, Customer-Defined Screens, and
Rules.
DC14
Picis also provides NPR Reports, CDS attributes, and custom application
programming
DC15
both on-site and remotely.
DC16
DC17
Please visit http://www.picis.com/services/technical/npr.asp# for more
information on what
DC18
Picis can do for your Meditech facility.
L1
D
N1
AL START start.macro
P1
SCRN
Yzcus.picis.bms.keyboardMIS.USER MIS.USER.zcus.picis.bms.keyboard2N N
CS
46484648
P1
,"_%MIS.USER.zcus.picis.bms.keyboard.M.s(0)_"%Z.on.device_______________________________________________ meditech-l mailing list [email protected] http://mtusers.com/mailman/listinfo/meditech-l