All messages should be posted in plain text. HTML will be converted to attachments. The meditech-l web site is MTUsers.com ======================================
We are implementing an other vendor interface to a SeeBeyond Datagate Interface Engine, which we have had in place for a number of years. We are running into a number of issues and I was wondering, if anyone else had encountered the same issues. 1. Occasionally the background communication processes stop processing messages but don't show any errors. When the detail of the process is viewed the time has been incrementing normally, but the process is not processing the messages. The outbound messages show QUEUED in the outbox. We have not setup alerts, but I assume the alerts would not show anything wrong either. None of our other interfaces have this issue. 2. Meditech appears to occasionally fail to process the ACK correctly for an outgoing message. It then sends a second copy of the identical message. Our receiving Laboratory System (not Meditech) receive the order for the same patient, same test and same time and cancels the order as a duplicate. When we examine the order it is a completely identical second order with the same message ID#. The receiving system is not capable of tracking duplicate ID#'s. We are currently scheduled for go-live on November 1 and any insights or assistance anyone could provide would be very much appreciated. John Bullock Director of Information Systems Valley Presbyterian Hospital 15107 Vanowen Street Van Nuys, CA 91405 [EMAIL PROTECTED] (818) 902-5779 _______________________________________________ meditech-l mailing list [email protected] http://mtusers.com/mailman/listinfo/meditech-l